Pinout visualiser
Choose how each end of a cable is terminated. The visualiser draws both ends in the real pair colours, follows every wire from one end to the other, and says whether the result is straight-through, a crossover, or miswired. Use Custom order to enter what you actually see on a jack, pin by pin, and it also points out split pairs.
| End A pin | Wire colour | End B pin |
|---|
How the visualiser works
There is no measurement and no formula beyond matching colours:
- Mapping: pin p at end A joins pin q at end B when the wire on pin p at end A has the same colour as the wire on pin q at end B.
- Straight-through: every pin joins the same pin number (1 to 1 through 8 to 8).
- Two-pair crossover: pins 1, 2, 3, 6 join 3, 6, 1, 2 and the other four go straight through. That is what a T568A end and a T568B end give you.
- Full crossover: pins 1, 2, 3, 6 cross as above and pins 4, 5, 7, 8 join 7, 8, 4, 5.
- Miswired: any other mapping. The tool lists each wire that lands on a different pin number.
- Split pair: pins 1-2, 3-6, 4-5 and 7-8 each carry one signal pair, so each of those pin pairs must hold one colour and its white-striped partner. If not, that end has a split pair.
Assumptions
- The cable has four twisted pairs in the standard colour code: blue, orange, green and brown, each with a white-striped partner.
- Pins are numbered 1 to 8 as the two wiring schemes number them. Read a jack's printed A or B colour label rather than guessing the pin order from its shape.
- The result is an estimate from the colours you choose. It cannot see a loose contact, a short or a broken wire; a cable tester's wire map checks the real cable.
- A network port with Auto-MDIX enabled can automatically configure supported straight-through and crossover connections (see the Cisco source below). Check your device's documentation; for a permanent run in the wall, wire both ends to the same scheme.
The two colour orders
The two wiring schemes, T568A and T568B, differ only in where the orange and green pairs go. The table follows the pin-by-pin charts published by trueCABLE and Fluke Networks (see Sources); the visualiser uses the same two sequences.
| Pin | T568A | T568B |
|---|---|---|
| 1 | White-orange | White-green |
| 2 | Orange | Green |
| 3 | White-green | White-orange |
| 4 | Blue | Blue |
| 5 | White-blue | White-blue |
| 6 | Green | Orange |
| 7 | White-brown | White-brown |
| 8 | Brown | Brown |
Sources
- trueCABLE, T568A vs T568B (Cable Academy), the pin-by-pin table for both schemes.
- Fluke Networks, Differences Between Wiring Codes T568A vs T568B, the front-view jack colour chart.
- Fluke Networks, Wire Map Testing: It's Not All About Color, for the four physical colour pairs, split pairs and the limits of a continuity test.
- Cisco, Catalyst 6807-XL hardware installation guide, cable specifications (Tables 8 and 9), for the straight-through and crossover pin rules.
- Cisco, Ethernet cabling and Auto-MDIX documentation (Appendix C), for automatic straight-through and crossover configuration.
- Telecommunications Industry Association (TIA), TIA publishes new standards ANSI/TIA-568.2-E and ANSI/TIA-568.5-1, used only to note that TIA has published the 568.2-E revision of the balanced twisted-pair standard; the standard itself is sold by TIA.
Read the guide on T568A and T568B pinouts and keystone punch-down for the termination steps.